OurCompany    Media Center    Containment Systems    Sealants    Thermal    Acoustic    Support  

Our Company
Home
Contact Us
Dealer Locator
Dealer Opportunities
News
MediaCenter
Videos
Containment
Sealants Gallery
Thermal Gallery Com
Thermal Gallery Res.
Slide Show
PDF Brochures
Interactive CD-ROM
Decibal (dB) Demo
Indoor Air Quality
Thermal Envelope
Test Your Knowledge
Containment Systems
Welcome
News
Projects Gallery
FAQs
Poly-X
Comparisons
PDF Brochures
Repair Services
Supplies & Equipment
Leak Detection
Tank Bottom Savers
Sealants
Welcome
News
Poly-X
FAQs
Advantages & Benefits
Applications
Colors
Comparison
Chemical Resistance
Definition
Equipment
History
Projects Gallery
PDF Brochures
Performance Chart
Pipeline
Roofing
Thermal
Welcome
3 Factors to Consider
Advantage Program
Architect Commercial
Architect Residental
Building Science
Case Studies
Cellulose
Corrosion
Energy Savings
FAQs - Cellulose
FAQs - Spray Foam
Fire Safety
Gallery Commercial
Gallery Residental
Healthy Home
Hotbox
News
Recycled
R Values
R Value Myth
R, K, C, & U Factors
Spray Faom
Steel Structures
Testimonials Builder
Testimonials Res.
Thermal Envelope
Vapor Retarders
Wall Strength
Questionnaire
Remodeling
Remodel Advantage
Acoustic
Welcome
Applications
FAQs-Architectural
FAQs-Basic
Acoustic Properties
Decibal (dB) Demo
Decibel (dB) Levels
Insulation * Absorption
Sound Proofing Myths
News
PDF Brochures
Peace-of-Mind
Support
Contact Us
PDF Brochures
News index
Glossary
Home
Site Index
Site Navigation Tips
Dealer Locator
Dealer Opportunities
Building Science
Code Resources
Industry Links

Vapor Retarders

 

All Tech Insulation products for thermal and sound control application in walls, floors and attics. When applied within exterior walls, we do not recommend the use of a vapor retarder on the warm-in-winter side, primarily due to All Tech Insulation Systems mass density and hygroscopic properties. This application without a vapor retarder is considered an alternate method under the provisions of Section 106 of the 1999 National Building Code (NBC), relating specifically to Chapter 13 and Section 723.3.1 and additionally to Sections 101.2 and 103.1 of the International Energy Conservation Code.

 

The 1997 ASHRAE Fundamentals Handbook, page 23.5 defines a heating climate of having 4000 or more annual heating degree-days. The climate of Michigan would fall under this definition, since heating degree-days range from a low of 6179 to a high of 9670 and an average of 7605 (ANSI/ASRAE Standard 90.2-1993, Section 9). The purpose of a vapor retarder is to retard moisture movement into an exterior wall where it might condense on the exterior sheathing during heating periods or the interior wall covering during cooling periods. In heating climates, it would be located on the inner side (warm-in-winter side) of the exterior wall.

 

According to the ASHRAE Handbook, page 23.8, the use of a vapor retarder at both exterior and interior locations is undesirable because it can restrict not only the entry of moisture into the insulation but the escape of any moisture as well. Section 1406.3.6 of the NVC requires a water-resistive barrier of 15-pound asphalt felt, which is classified as a vapor retarder (ASHRAE Handbook, page 24.17), to be attached to the sheathing behind the exterior wall veneer. This creates a technical problem between the requirements of building code and energy code. A vapor retarder on both sides of the exterior wall was determined to be one of the aggravating causes for EIFS system failures in North Carolina, Washington and Vancouver, B.C.

 

Because of its mass density (high airflow resistance) and hygroscopic properties (moisture holding), All Tech Insulation has the capacity to store up to 30% of its weight in moisture vapor while retarding its passage by air movement. In other words, it retards the flow of moisture vapor, and performs best when moisture vapor is allowed to enter or exit from either side. The chance of any significant amount of moisture vapor actually passing completely through from one side of the insulation to the other is highly unlikely given the dynamics of our daily environment.

 

Additionally, since the intent of the energy code regarding the use of vapor retarders is to avoid creating "….conditions of accelerated deterioration from moisture condensation…", it would not be prudent to risk the possibility that moisture or water could become trapped within the wall by vapor retarders on both sides.

 

Contact an All Tech Insulation engineer today (989-826-9999) for a deeper discussion about your insulation requirements.